INFLUENCE OF ULTRASOUND ON THE ARTERIAL SIDE DAMAGE DEPENDING ON THE HEAD OF THE WAVE GUIDE STRUCTURE

https://doi.org/10.51523/2708-6011.2009-6-3-26

Abstract

The aim of the study: to study the influence of various ultrasound parameters on a damage rate of an arterial side depending on a head of a wave guide structure in vivo. It is shown, that the damage rate of a vascular side increases with the growth of intensity of ultrasonic influence and depends on a head of a wave guide structure. Porosity in a range from 15 to 45 % does not influence on a damage rate of a vascular side.

About the Authors

I. E. Adzerikho
Belarusian Medical Academy Post Gradual Education
Belarus


N. N. Yafimava
Gomel State Medical University
Belarus


R. V. Doroshenko
Gomel State Medical University
Belarus


References

1. Профилактика сердечно-сосудистых заболеваний - реальный путь улучшения демографической ситуации в России / Р. Г. Оганов [и др.] // Кардиология. - 2007. - № 1. - С. 4-7.

2. Государственная программа по формированию здорового образа жизни населения Республики Беларусь [Электронный ресурс]. - 2007. - Режим доступа: http: // www.minzdrav.by. - Дата доступа: 10.05.2008.

3. Тромбоз стента у пациентов с острым инфарктом миокарда / С. В. Роган [и др.] // Кардиология. - 2003. - Т. 43, № 2. - С. 77-81.

4. Serial intravascular ultrasound assessment of the efficacy of intracoronary gamma-radiation therapy for preventing recurrence in very long, diffuse, in-stent restenosis lesions / J. M. Ahmed [et al.] // Circulation. - 2001. - Vol. 104, № 8. - P. 856-859.

5. The impact of the stent era on the management strategy for acute myocardial infarction: A population-based perspective / H. L. Dauerman [et al.] // Catheter Cardiovasc Interv. - 2000. - Vol. 11, № 51. - Р. 255-258.

6. Procedural results and late clinical outcomes after percutaneous interventions using long (> or = 25 mm) versus short (< 20 mm) stents / R. Kornowski [et al.] // J. Am. Coll. Cardiol. - 2000. - Vol. 35, № 3. - Р. 612-618.

7. Experimental ultrasonic angioplasty: disruption of atherosclerotic plaques and thrombi in vitro and arterial recanalization in vivo / U. Rosenschein [et al.] // J. Am. Coll. Cardiol. - 1990. - Vol. 15, № 3. - P. 711-717.

8. Ultrasound arterial recanalization in acute myocardial infarction / C. A. Monteverde [et al.] // Circulation. - 1990. - Vol. 62. - P. 2473.

9. Siegel, R. J. Ultrasound augmentation of thrombolysis and tissue perfusion / R.J. Siegel // Clin. Physiol. Funct. Imaging. - 2004. - Vol. 24. - P. 156-163.

10. Effect of 40-kHz ultrasound on acute thrombotic ischemia in a rabbit femoral artery thrombosis model / V. N. Suchkova [et al.] // Circulation. - 2000. - Vol. 101. - P. 2296-2301.

11. Does external ultrasound accelerate thromolysis? / R. Kornowski [et al.] // Circulation. - 1994. - Vol. 89. - P. 339-344.

12. Тун, Цзяи. Эффективность восстановления проходимости пораженных атеросклерозом артерий ультразвуковыми волноводами различных модификаций in vitro: автореф. … дис. канд. мед. наук: 14.00.06/ Цзяи Тун; БелМАПО. - Мн., 2006. - 21 с.


Review

For citations:


Adzerikho I.E., Yafimava N.N., Doroshenko R.V. INFLUENCE OF ULTRASOUND ON THE ARTERIAL SIDE DAMAGE DEPENDING ON THE HEAD OF THE WAVE GUIDE STRUCTURE. Health and Ecology Issues. 2009;(3):121-125. (In Russ.) https://doi.org/10.51523/2708-6011.2009-6-3-26

Views: 250


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2220-0967 (Print)
ISSN 2708-6011 (Online)